SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Mounting Type Type Base Product Number Approval Agency Termination Style Output Voltage - Supply DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Accuracy Response Time Input Range Isolation
P42100D3-0003 Knick P42100D3-0003 1.0000
RFQ
ECAD 5 0.00000000 Knick VariTrans Box Active -10°C ~ 70°C DIN Rail Voltage Transducer UL Screw Terminal 4 ~ 20mA 20 ~ 253VAC/DC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2834-P42100D3-0003 3A001 8543.70.9099 1 ±0.3% 110µs 0 ~ 3600V 3600VAC/DC (Working), 15000VAC (Test)
RISH CON-CV-AVG-14-F-I-02-H Rishabh Instruments RISH CON-CV-AVG-14-F-I-02-H -
RFQ
ECAD 7707 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 4 ~ 20mA 40 ~ 300VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-14-F-I-02-H 1 - 250ms 0 ~ 500VAC -
RISH CON-CV-AVG-01-F-V-02-L Rishabh Instruments RISH CON-CV-AVG-01-F-V-02-L 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 0 ~ 5VDC 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-01-F-V-02-L 1 - 250ms 0 ~ 63.5VAC -
DN-848VI-150V ICP DAS USA INC DN-848VI-150V 899.0000
RFQ
ECAD 30 0.00000000 ICP DAS USA INC DN-848VI Box Active -25°C ~ 75°C DIN Rail Voltage Transducer DN-848VI CE, FCC - ±10V 10 ~ 24VDC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2488-DN-848VI-150V EAR99 1 1% - ±150V 3000VAC (Test)
P29000P2/01 Knick P29000P2/01 1.0000
RFQ
ECAD 5560 0.00000000 Knick VariTrans Box Active -25°C ~ 70°C DIN Rail Voltage Transducer cULus Screw Terminal ±20mA, ±10V (Configurable) 20 ~ 230VAC/DC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2834-P29000P2/01 3A001 8543.70.9099 1 ±0.2% 200µs ±1000V (Configurable) 1000VAC/DC (Working), 5400VAC (Test)
ENTUBE SE STD (1000V 200MV) Verivolt LLC ENTUBE SE STD (1000V 200MV) 260.8800
RFQ
ECAD 1485 0.00000000 Verivolt LLC Entube SE Box Active -35°C ~ 70°C Free Hanging (In-Line) Voltage Transducer CE BNC ±200mV - download 1 (Unlimited) 1780-ENTUBESESTD(1000V200MV) 1 ±0.2% - ±1000V -
2810625 Phoenix Contact 2810625 390.6700
RFQ
ECAD 3954 0.00000000 Phoenix Contact MCR Bulk Active -20°C ~ 65°C DIN Rail Current Transducer ATEX, cULus Screw Terminal 0 ~ 20mA 19.2 ~ 253VAC/DC download RoHS Compliant 1 (Unlimited) EAR99 8538.90.1000 1 - 200ms 0 ~ 5A 4000VAC (Test)
CM21-V7SF550000000 Rishabh Instruments CM21-V7SF550000000 44.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer CE, UL Screw Terminal 4 ~ 20mA 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-CM21-V7SF550000000 1 - 250ms 0 ~ 440VAC -
ENTUBE DE-HB (1000V 1V DIFF SC) Verivolt LLC ENTUBE DE-HB (1000V 1V DIFF SC) 472.0700
RFQ
ECAD 3998 0.00000000 Verivolt LLC Entube DE-HB Box Active 0°C ~ 70°C DIN Rail Voltage Transducer CE Spring Terminal ±1V 8 ~ 28VDC - 1 (Unlimited) 1780-ENTUBEDE-HB(1000V1VDIFFSC) 1 ±0.2% 20ns ±1000V -
CM21-A62G540000000 Rishabh Instruments CM21-A62G540000000 44.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Current Transducer CE, UL Screw Terminal 2 ~ 10mA 40 ~ 300VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-CM21-A62G540000000 1 - 250ms 0 ~ 1A -
ENTUBE DE (1500V 10V) Verivolt LLC ENTUBE DE (1500V 10V) 347.8400
RFQ
ECAD 1 0.00000000 Verivolt LLC Entube DE Box Active -25°C ~ 70°C DIN Rail Voltage Transducer ENTUBE DE - Spring Terminal ±10V - download RoHS Compliant 1 (Unlimited) 1780-1139 EAR99 9030.33.3800 1 ±0.2% - ±1500V -
RISH CON-CV-AVG-09-F-I-02-L Rishabh Instruments RISH CON-CV-AVG-09-F-I-02-L 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 4 ~ 20mA 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-09-F-I-02-L 1 - 250ms 0 ~ 300VAC -
RISH CON-CV-AVG-12-F-I-01-L Rishabh Instruments RISH CON-CV-AVG-12-F-I-01-L 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 0 ~ 20mA 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-12-F-I-01-L 1 - 250ms 0 ~ 440VAC -
ENTUBE DE-HB (500V 10V DIFF SC) Verivolt LLC ENTUBE DE-HB (500V 10V DIFF SC) 472.0700
RFQ
ECAD 4371 0.00000000 Verivolt LLC Entube DE-HB Box Active 0°C ~ 70°C DIN Rail Voltage Transducer CE Spring Terminal ±10V 8 ~ 28VDC - 1 (Unlimited) 1780-ENTUBEDE-HB(500V10VDIFFSC) 1 ±0.2% 20ns ±500V -
CM21-V62F550000000 Rishabh Instruments CM21-V62F550000000 44.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer CE, UL Screw Terminal 4 ~ 20mA 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-CM21-V62F550000000 1 - 250ms 0 ~ 1A -
CR4850-50 CR Magnetics Inc. CR4850-50 191.6400
RFQ
ECAD 4683 0.00000000 CR Magnetics Inc. CR4800 Bulk Active 0°C ~ 60°C DIN Rail Average RMS AC Voltage Transducer CE, cURus Screw Terminal 0 ~ 5VDC 24VDC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 9030.33.3400 1 0.5% 250ms 0 ~ 50VAC 2500VDC
ENTUBE DE-HB (1000V1V SESC) Verivolt LLC ENTUBE DE-HB (1000V1V SESC) 416.1000
RFQ
ECAD 3114 0.00000000 Verivolt LLC Entube DE-HB Box Active -25°C ~ 70°C DIN Rail Voltage Transducer ENTUBE DE - Spring Terminal ±1V 9 ~ 28VDC download RoHS Compliant 1 (Unlimited) EAR99 9030.33.3800 1 ±0.2% 20ns ±1000V -
ISOBLOCK V-1C (10V 10V 0.1%) Verivolt LLC ISOBLOCK V-1C (10V 10V 0.1%) 571.4600
RFQ
ECAD 1066 0.00000000 Verivolt LLC IsoBlock V Box Active -25°C ~ 70°C DIN Rail Voltage Transducer CE Spring Terminal ±10V 12 ~ 28VDC download 1 (Unlimited) 1780-ISOBLOCKV-1C(10V10V0.1%) 1 ±0.1% 3µs ±10V 1500V (Working)
ENTUBE SE STD (2000V) Verivolt LLC ENTUBE SE STD (2000V) 252.0000
RFQ
ECAD 9295 0.00000000 Verivolt LLC Entube SE Box Active -25°C ~ 70°C - Voltage Transducer ENTUBE SE - BNC, SHV ±5V - download RoHS Compliant 1 (Unlimited) EAR99 9030.33.3800 1 ±0.2% - ±2000V -
ENTUBE SE STD (2000V 200MV) Verivolt LLC ENTUBE SE STD (2000V 200MV) 260.8800
RFQ
ECAD 2308 0.00000000 Verivolt LLC Entube SE Box Active -35°C ~ 70°C Free Hanging (In-Line) Voltage Transducer CE BNC ±200mV - download 1 (Unlimited) 1780-ENTUBESESTD(2000V200MV) 1 ±0.2% - ±2000V -
ENTUBE SE STD (500V 1V) Verivolt LLC ENTUBE SE STD (500V 1V) 260.8800
RFQ
ECAD 4932 0.00000000 Verivolt LLC Entube SE Box Active -35°C ~ 70°C Free Hanging (In-Line) Voltage Transducer CE BNC ±1V - download 1 (Unlimited) 1780-ENTUBESESTD(500V1V) 1 ±0.2% - ±500V -
RISH CON-CV-AVG-01-F-I-01-H Rishabh Instruments RISH CON-CV-AVG-01-F-I-01-H 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 0 ~ 20mA 40 ~ 300VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-01-F-I-01-H 1 - 250ms 0 ~ 63.5VAC -
P52100K11-M6M/11 Knick P52100K11-M6M/11 1.0000
RFQ
ECAD 10 0.00000000 Knick ProLine Box Active -40°C ~ 85°C DIN Rail Voltage Transducer UL Screw Terminal ±20mA, ±10V (Configurable) 24 ~ 230VAC/DC download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 2834-P52100K11-M6M/11 3A001 8543.70.9099 1 ±0.1% 60µs ±4200V (Configurable) 4800VAC/DC (Working), 16000VAC (Test)
RISH CON-CV-AVG-02-F-I-02-L Rishabh Instruments RISH CON-CV-AVG-02-F-I-02-L 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 4 ~ 20mA 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-02-F-I-02-L 1 - 250ms 0 ~ 100VAC -
CM21-V7SG550000000 Rishabh Instruments CM21-V7SG550000000 44.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer CE, UL Screw Terminal 4 ~ 20mA 40 ~ 300VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-CM21-V7SG550000000 1 - 250ms 0 ~ 440VAC -
RISH CON-CV-AVG-06-F-I-04-L Rishabh Instruments RISH CON-CV-AVG-06-F-I-04-L 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 2 ~ 10mA 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-06-F-I-04-L 1 - 250ms 0 ~ 230VAC -
RISH CON-CV-AVG-12-F-V-01-L Rishabh Instruments RISH CON-CV-AVG-12-F-V-01-L 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 0 ~ 10VDC 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-12-F-V-01-L 1 - 250ms 0 ~ 440VAC -
RISH CON-CV-AVG-03-F-I-04-L Rishabh Instruments RISH CON-CV-AVG-03-F-I-04-L 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Voltage Transducer UL Screw Terminal 2 ~ 10mA 24 ~ 60VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CV-AVG-03-F-I-04-L 1 - 250ms 0 ~ 110VAC -
ENTUBE QE (150VAC 7VAC L-N ) Verivolt LLC ENTUBE QE (150VAC 7VAC L-N ) 223.6100
RFQ
ECAD 3971 0.00000000 Verivolt LLC Entube QE Box Active -25°C ~ 70°C DIN Rail Voltage Transducer CE RJ45, Spring Terminal 0 ~ 7VAC - download 1 (Unlimited) 1780-ENTUBEQE(150VAC7VACL-N) 1 ±0.2% - 0 ~ 150VAC -
RISH CON-CA-AVG-05-F-I-02-H Rishabh Instruments RISH CON-CA-AVG-05-F-I-02-H 33.0000
RFQ
ECAD 5 0.00000000 Rishabh Instruments - Bulk Active 0°C ~ 45°C DIN Rail Current Transducer UL Screw Terminal 4 ~ 20mA 40 ~ 300VAC/DC download ROHS3 Compliant Not Applicable REACH Unaffected 4080-RISHCON-CA-AVG-05-F-I-02-H 1 - 250ms 0 ~ 5A -
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse